HOW OFC WORKS?

Fiber-optic cable employs photons for the transmission of digital signals across a strand of ultrapure silica (or plastic in some cases). Optical systems operate in the infrared light range. Photons pass through the cable with negligible resistance. The silica is so pure that, according to Michael Coden of Codenoll Technologies Corporation, a 3-mile-thick window made of the purified silica would give you the same view as a 1/8-inch-thick glass window. As optical system requirements increase, the purity of the cable becomes even more important. The best cable from Corning and Lucent is free of all but the smallest trace elements of iron and other metals, as well as hydroxyl ions, which are present due to water molecules in the cable.

A fiber-optic cable guides light from end to end. A signal is injected in one end by an LED (light-emitting diode) or by semiconductor lasers. LEDs can generate signals up to about 300 Mbits/sec. Lasers can generate signals in the multi-gigabit/sec range. LEDs are used for short-distance optical links such as enterprise backbones while lasers are used for longer distance networks. Lasers are also capable of the higher power levels needed for long-haul backbone links.

Lasers produce light in "windows" of the near infrared range as listed in the following table. A window is an infrared range that is optimized for optical transmissions. The ITU recently defined the following spectral bands in order to clarify the terminology that is used for fiber-optic systems. These definitions are meant for classification purposes only.

Band

Descriptor

Range (nm)

O band

Original

1260 to 1360

E band

Extended

1360 to 1460

S band

Short wavelength

1460 to 1530

C band

Conventional

1530 to 1565

L band

Long wavelength

1565 to 1625

U band

Ultralong wavelength

1625 to 1675

Figure 1 illustrates the structure of fiber-optic cable. The core is the transparent silica (or plastic) through which the light travels. The cladding is a glass sheath that surrounds the core. The cladding acts like a mirror, reflecting light back into the core. The cladding itself is covered with a plastic coating and strength material when appropriate.

Figure 1

Figure F-2 illustrates the different paths that light will take through a fiber cable, depending on the type of cable. If the core is wide and there is a sharp transition between the core and the cladding, high-order rays will follow reflected paths while low-order modes will follow straighter paths. This causes some of the rays to arrive at the source at a different time-a phenomenon called modal dispersion, as discussed later. Dispersion limits cable distance. Graded-index cable can help resolve the problem, or a small core can be used as in the single-mode cable. An animation that demonstrates the way that light travels through fiber cable is at the Bell Labs Web site given later.

Figure 2

Plastic core cable is used for short-distance applications, such as airplane wiring and wiring for some buildings. The remainder of this topic covers silica-based fiber-optic cable.

Silica cable is categorized as either multimode cable, which is used for short-distance connections (LANs, campus networks, and short-distance metro networks), or single-mode cable that is used for long-distance (cross-country networks and intercontinental submarine links). The light source for the former is typically an LED, while the light source for the latter is a laser. Long-haul fiber-optic cable is often bundled with anywhere from 100 to 800 fibers per cable.

  • Multimode cable This cable has a relatively large diameter core (50 to 80 microns) and a total diameter of 125 microns. Step-index multimode cable has an abrupt change between core and cladding while graded-index multimode cables has a gradual change between core and cladding. The former is limited to about 50 Mbits/sec, while the latter is limited to 1 Gbit/sec. With graded cable, the amount of refraction gradually drops outward from the core. Light travels faster in a material in which refraction is lower. This causes the light traveling through the outer material to travel faster than light at the core. The end result is that all the light tends to arrive at the same time. But this fix still has distance limitations.

  • Single mode (monomode) cable The single-mode cables are the most important cables for long-haul use (carrier and Internet core). The cable has a small core (7 to 10 microns) that forces the light to follow a more linear single path down the cable, as opposed to the multipath reflections of multimode cable. However, another form of dispersion, called chromatic dispersion, is a problem (as discussed later). Lasers are the usual light source. This cable is the most expensive and hardest to handle, but it has the highest bandwidths and distance ratings.

Cable specifications list the core and cladding diameters as fractional numbers. For example, the minimum recommended cable type for FDDI (Fiber Distributed Data Interface) is 62.5/125-micron multimode fiber-optic cable. That means the core is 62.5 microns and the core with surrounding cladding is a total of 125 microns. The cladding diameter must be the same when joining cables because connectors typically use the cladding diameter as a guide for aligning the core.

  • The core specifications for step-index and graded-index multimode cables is typically 50, 62.5, or 100 microns. The cladding diameter for step-mode cable is 125 microns.

  • The core diameter for single-mode cable is typically 7 to 10 microns with a cladding diameter of 125 microns.

The ITU has defined a series of recommendations that describe the geometrical properties and transmissive properties of multimode and single-mode fiber-optic cables. The four most important recommendations are listed here:

  • ITU G.651 Covers multimode graded-index fiber-optic cable having a 50-micron nominal core diameter and a 125-micron nominal cladding diameter.

  • ITU G.652 Covers single-mode NDSF (non-dispersion-shifted fiber). This cable constitutes most of the cable that was installed in the 1980s. Transmissions take place in the 1,310-nm range where there is minimal signal dispersion. Dispersion causes signal problems over long distances, as described later. G.652 cable supports the following distances and data rates: 1000 km at 2.5 Gbits/sec, 60 km at 10 Gbits/sec, and 3 km at 40 Gbits/sec.

  • ITU G.653 Covers single-mode dispersion-shifted optical fiber cable. The cable is designed in a way to "shift" the region where dispersion is minimized to the 1,550-nm wavelength range. At this range attenuation is also minimized, so longer distance cables are possible.

  • ITU G.655 Covers single-mode NZ-DSF (nonzero dispersion-shifted fiber) cable, which takes advantage of dispersion characteristics that suppress the growth of four-wave mixing, an effect that is harmful to WDM (wavelength division multiplexing) systems. NZ-DSF supports high-power signals and longer distances, as well as closely spaced DWDM (dense WDM) channels at rates of 10 Gbits/sec or higher. Lucent True Wave is an example of this cable. It supports the following distances and data rates: 6000 km at 2.5 Gbits/sec, 400 km at 10 Gbits/sec, and 25 km at 40 Gbits/sec.

G.655 is the latest development in fiber-optic cable. In particular, G.655 is optimized for WDM and long-distance cable runs such as submarine cables. It uses dispersion to advantage. Dispersion can help reduce an effect called four-wave mixing (FWM), which occurs in DWDM systems when three wavelengths mix in such a way to produce a fourth wavelength that overlays and interferes with the original signals.

With DWDM, a single fiber can potentially carry thousands of lambda circuits. A lambda is a specific subwavelength of light within one of the windows of light. It provides all the capabilities of an individual circuit. Lambdas are set up using frequency division multiplexing. Think of each lambda as a specific color of infrared light transmitting at 10 Gbits/sec or more. An optical multiplexer divides the available spectrum on the cable up into many individual lambdas. For example, the Avanex PowerMux can put over 800 channels on a single fiber with spacing between channels of 12.5 gigahertz. With the potential of thousands of lambdas per fiber, it is practical for carriers to lease entire optical wavelengths to businesses. See "Optical Networks."

An alternative to DWDM are new optical modulation techniques that boost the capacity of existing cables. Kestrel Solution's Optical FDM combines FDM (frequency division multiplexing), DSP (digital signal processing), and optical modulation to improve performance on existing fiber cables, especially in metropolitan areas where low-quality fiber has been installed (due to short distances) and in SONET systems. Optical FDM gives full access to the total bandwidth of the cable.

Cable Performance Characteristics

Fiber cable has certain characteristics that limit its performance. Cable from different manufacturers may exhibit variations in these characteristics. The primary performance limiters are attenuation and dispersion.

Attenuation, EDFAs, and Raman Amplifiers

Attenuation is signal loss over distance. Think of the light pulses as loosing their energy and flattening out as they travel down the cable. High attenuation will result in errors at the receiver. Attenuation is not a problem for metro-area networks, but it puts distance limitations on long- haul backbone networks. Three types of devices may be used to overcome attenuation:

  • Electronic regenerator This device regenerates signals by first converting optical signals to electrical signals. The electrical signal is regenerated, converted back to optical, and injected back into the fiber. Regenerators are too inefficient for modern high-speed optical networks due to electrical regeneration requirements. On WDM systems, each wavelength requires its own opto-electric amplifier, an expensive proposition if there are many wavelengths.

  • EDFA (erbium-doped fiber amplifier) This device is an amplifier rather than a signal regenerator. It directly amplifies optical signals without a need to do the optical-to- electrical conversion. An EDFA contains a short strand of erbium-doped fiber and two signal inputs. One input is the optical signal that needs to be amplified. The other is light from a pump laser that excites the erbium atoms so that they give up photons that amplify incoming optical signal photons as described later. Thank Albert Einstein for this "trick" of light magic.

  • EDFA/Raman amplifier combination Raman amplification is an add-on component that enhances EDFA optical amplifiers. At each EDFA amplifier, a Raman pump injects high-power laser light into the fiber in the opposite direction of the source signal. The injected photons boost the optical signal where it is needed most-at the far end of the laser signal where it is experiencing the most attenuation. Raman amplification can create signal gain of up to 10 dB, which allows longer distance cable runs. It also allows optical networks to obtain transmission rates as high as 40 Gbits/sec.

EDFAs are crucial to WDMA systems because a single amplifier boosts all the wavelengths simultaneously. With older electrical regenerators, one regenerator is required for each wavelength, meaning that an entire stack of regenerators is needed at each regeneration point.

The 1,550 range (C band) is often called "erbium window" because the energy level of erbium ions is close to the energy level of photons in the C band. Through the process of stimulated emission, erbium can be coaxed into releasing energy that amplifies light in the C-band. The process is as follows. The EDFA amplifier pumps photons into the erbium-doped cable. Erbium atoms absorb photons, which cause electrons to jump to a temporary excited state. When an electron decays, it releases a photon that is absorbed by the signal photons. Thus, the optical signal passing through the cable is amplified without any electrical conversion.

Dispersion

Another characteristic is dispersion, which is the broadening of a light pulse as it travels down the cable. Excessive dispersion will make a signal difficult to read by the receiver. When an LED or laser sends light into a multimode fiber, a range of wavelengths of light is present. Some of those wavelengths travel at different speeds than others. The effect is to distort waveforms, which can cause errors in reading the signal at the other end of the cable. Graded-index cable is designed to minimize the delay of the slower wavelengths.

There are four types of dispersion:

  • Material dispersion Variations in the refractive properties of the cable cause signal dispersion.

  • Modal dispersion Occurs in multimode cable. Light takes different paths through the cable with light on some paths having a longer travel time than others. Graded cable balances this effect.

  • Chromatic dispersion This occurs because some wavelengths travel through a medium faster than others. The longer the cable, the worse the effect, and the harder it is to read the signal.

  • Waveguide dispersion This dispersion occurs in single-mode fiber due to the difference in the speed of the signal between the core and the cladding. It causes chromatic dispersion.

G.652 cable, used in most commercial systems, takes advantage of the 1,310-nm window where chromatic dispersion is minimized. This window is often called the zero-dispersion point-it is the range where chromatic dispersion is minimized because the waveguide dispersion cancels out material dispersion.

Long-haul carriers, on the other hand, have higher bandwidth and distance requirements, so G.653 and G.655 "dispersion-shifted" fiber operating in the C band is preferred. The C band is used for DWDM systems, which support many closely spaced channels at data rates of 10 Gbits/sec and higher. Two other bands are now being used to boost capacity and distance: the 1,460 nm to 1,530 nm S band and the 1565 to 1625 L band. A newer approach employs soliton technology, which can be used to create a cable system that stretches nearly halfway around the world. See "Soliton."

Note that it is possible to support DWDM on many older fiber cables. Standard single- mode fiber will support DWDM at lower data rates. Some older dispersion-shifted fibers were not able to handle DWDM, but these cables may be made to act like nonzero dispersion cable by using wavelength above and below the 1,550-nm window.

Corning and Lucent are the major providers of long-haul cable. Lucent's TrueWave and AllWave cables are made of single-mode nonzero dispersion fibers that support all the wavelength windows. TrueWave is specifically designed for optically amplified, high-powered long-distance DWDM networks operating in both the C band and the L band. Both cable types are manufactured with a patented purification process to remove water molecules in the core, thus allowing wider spectrum usage.

Corning's LEAF is a single-mode NZ-DSF fiber designed for DWDM systems. It combines low attenuation and low dispersion with an effective area that is 32 percent larger than non- NZ-DSF fiber. This allows more power to be pumped into the network over more channels without nonlinear effects that create noise, distort signals, and degrade performance. It can operate at 10 Gbits/sec or higher using high-output-power EDFAs.

Corning's MetroCor fiber is a single-mode NZ-DSF cable optimized for short-distance metropolitan usage. It does not require the powerful lasers that are required in the long-haul environment and so helps reduce the cost of implementing metropolitan fiber networks.

For more information about metropolitan optical networks, see "FTTH (Fiber to the Home)," "MAN (Metropolitan Area Network)," and "PON (Passive Optical Network)."

Using of OTDR

Fiber Optic Cable Plant Link Loss Budget Analysis

Loss budget analysis is the calculation and verification of a fiber optic system's operating characteristics. This encompasses items such as routing, electronics, wavelengths, fiber type, and circuit length. Attenuation and bandwidth are the key parameters for budget loss analysis.

Analyze Fiber Optic Link Loss In The Design Stage
Prior to designing or installing a fiber optic system, a loss budget analysis is reccommended to make certain the system will work over the proposed link. Both the passive and active components of the circuit have to be included in the budget loss calculation. Passive loss is made up of fiber loss, connector loss, and splice loss. Don't forget any couplers or splitters in the link. Active components are system gain, wavelength, transmitter power, receiver sensitivity, and dynamic range. Prior to system turn up, test the circuit with a source and FO power meter to ensure that it is within the loss budget.

The idea of a loss budget is to insure the network equipment will work over the installed fiber optic link. It is normal to be conservative over the specifications! Don't use the best possible specs for fiber attenuation or connector loss - give yourself some margin!

The best way to illustrate calculating a loss budget is to show how it's done for a 2 km multimode link with 5 connections (2 connectors at each end and 3 connections at patch panels in the link) and one splice in the middle. See the drawings below of the link layout and the instantaneous power in the link at any point along it's length, scaled exactly to the link drawing above it.

fiber optic cable

Fiber Optic Cable Plant Passive Component Loss

Step 1. Fiber loss at the operating wavelength

Cable Length 2.0 2.0

Fiber Type Multimode
Singlemode
Wavelength (nm) 850 1300 1300 1550
Fiber Atten. dB/km 3 [3.5] 1 [1.5] 0.4 [1/0.5] 0.3 [1/0.5]
Total Fiber Loss 6.0 [7.0] 2.0 [3.0]

(All specs in brackets are maximum values per EIA/TIA 568 standard. For singlemode fiber, a higher loss is allowed for premises applications. )

Step 2. Connector Loss
Multimode connectors will have losses of 0.2-0.5 dB typically. Singlemode connectors, which are factory made and fusion spliced on will have losses of 0.1-0.2 dB. Field terminated singlemode connectors may have losses as high as 0.5-1.0 dB. Let's calculate it at both typical and worst case values.

Connector Loss 0.3 dB (typical adhesive/polish conn) 0.75 dB (TIA-568 max acceptable)
Total # of Connectors 5 5
Total Connector Loss 1.5 dB 3.75 dB

(All connectors are allowed 0.75 max per EIA/TIA 568 standard)

Step 3. Splice Loss
Multimode splices are usually made with mechanical splices, although some fusion splicing is used. The larger core and multiple layers make fusion splicing abut the same loss as mechanical splicing, but fusion is more reliable in adverse environments. Figure 0.1-0.5 dB for multimode splices, 0.3 being a good average for an experienced installer. Fusion splicing of singlemode fiber will typically have less than 0.05 dB (that's right, less than a tenth of a dB!)

Typical Splice Loss 0.3 dB
Total # splices 1
Total Splice Loss 0.3 dB

(All splices are allowed 0.3 max per EIA/TIA 568 standard)

Step 4. Total Passive System Attenuation
Add the fiber loss, connector and splice losses to get the link loss.


Best Case TIA 568 Max
850 nm 1300 nm 850 nm 1300 nm
Total Fiber Loss (dB) 6.0 2.0 7.0 3.0
Total Connector Loss (dB) 1.5 1.5 3.75 3.75
Total Splice Loss (dB) 0.3 0.3 0.3 0.3
Other (dB) 0 0 0 0
Total Link Loss (dB) 7.8 3.8 11.05 7.05

Remember these should be the criteria for testing. Allow +/- 0.2 -0.5 dB for measurement uncertainty and that becomes your pass/fail criterion.

Equipment Link Loss Budget Calculation: Link loss budget for network hardware depends on the dynamic range, the difference between the sensitivity of the receiver and the output of the source into the fiber. You need some margin for system degradation over time or environment, so subtract that margin (as much as 3dB) to get the loss budget for the link.

Step 5. Data From Manufacturer's Specification for Active Components (Typical 100 Mb/s link)

Operating Wavelength (nm) 1300
Fiber Type MM
Receiver Sens. (dBm@ required BER) -31
Average Transmitter Output (dBm) -16
Dynamic Range (dB) 15
Recommended Excess Margin (dB) 3

Step 6. Loss Margin Calculation

Dynamic Range (dB) (above) 15 15
Cable Plant Link Loss (dB) 3.8 (Typ) 7.05 (TIA)
Link Loss Margin (dB) 11.2 7.95

As a general rule, the Link Loss Margin should be greater than approximately 3 dB to allow for link degradation over time. LEDs in the transmitter may age and lose power, connectors or splices may degrade or connectors may get dirty if opened for rerouting or testing. If cables are accidentally cut, excess margin will be needed to accommodate splices for restoration.

NOTE: Many techs forget when doing a loss budget that the connectors on the end of the cable plant must be included in the loss budget. When the cable plant is tested, the reference cables will mate with those connectors and their loss will be included in the measurements.

Related Fiber Optic Components Links
Types of Fiber Optic Cables
Fiber Optic Loss Budget Standard
Fiber Optic Connector Types
Troubleshooting Fiber Optic Transmitters & Receivers
Fiber Optic Couplers & Splitters
Fiber Optical Amplifiers

Fiber Optic Cable

Fiber Optic Cable

  • Uses light instead of electricity to transmit signals
  • Fiber is glass or plastic
  • Light source is laser or LEDs
  • Can transmit huge distances compared to copper cable
  • No EMI, hard to intercept

Fiber optics

Single Core.

A data transmission medium consisting of glass or plastic fibers. Light-emitting diodes (LEDs) or lasers send light through the fiber to a detector, which then converts the light back into electrical signals. Fiber-optics offer immense bandwidth, as well as protection from eavesdropping, electromagnetic interference, and radioactivity. Fiber-optic cabling employs one or more optical fibers, consisting of a central glass or plastic fiber, glass cladding, and a plastic outer sheath. Fiber-optic cable carries information as light instead of electricity, and can carry much more information over greater distances than copper cabling.

Optical principles
Fiber can transmit light a long distance because it keeps it in a channel. This is accomplished by surrounding the inner fiber with a cladding that has a different refractive index. This keeps the light bouncing along from side to side until the end.



Fiber optic cable
Figure 21: The structure of fiber optic cable

Single-mode cable
Single mode cable only has one light beam in it. The cable has a small diameter core and is made of the purest glass. A laser is usually the light source and the cable can extend several kilometers without a repeater.

Multimode cable
Multimode cable has greater capacity because several light beams are sent down it. The beams enter at slightly different angles and therefore don’t interfere with each other. The core is wider than used in single-mode and often made of fine plastic. Instead of lasers, the light source is usually light emitting diodes (LEDs). The system has greater capacity and is less expensive than single-mode. On the other hand, multimode doesn’t have the same reach, often restricted to hundreds of meters instead of kilometers. For this reason, multimode is usually used inside buildings, whereas single-mode is used between buildings and long distances. If the cable needs to be extended, optical repeaters are used.

The conductors in the cable only carry signals in one direction, therefore two conductors are used, each carrying signals in the opposite direction. The two cables are connected together with Kevlar webbing.

Pros and cons
Fiber optic cable has the longest range and should be used when long distance is a requirement. It has extremely high bandwidth, in the Gbps range. It is also immune to electrical interference, nor does it give off any of its own. This would be a factor in dangerous environments where an electrical spark could set off an explosion, say in an explosives factory. Finally, it is extremely difficult, but not impossible, to tap into a fiber optic system.

On the negative side, fiber optic cable is the most expensive to install. The cable and connectors are more expensive plus the installation requires highly skilled craftsmen. This is particularly true when two fibers need to be spliced together.

Connectors used for fiber cable are SC connectors which are a push and pull connector and ST connectors which are a bayonet mount.